Skip to main content

DLSOLAR Off-Grid Solar

Definitions as they are used in off-grid system design, not marketing. Where a term is commonly misused, the note explains the practical difference.

A-C

Absorption charge
The constant-voltage stage at the end of bulk charging, held until current falls to a set fraction of capacity. Too short and the battery stays undercharged; too long and it ages faster.
Albedo
The fraction of sunlight reflected from the ground. Snow raises it, dark soil and water lower it. Relevant to bifacial modules and to panels mounted over reflective surfaces.
Ampere-hour (Ah)
Charge capacity. Meaningless without a voltage — 100 Ah at 12 V is 1,280 Wh, not a fixed amount of energy.
Autonomy
The number of consecutive days a system can run its load with no meaningful solar input. Set by battery capacity and usable depth of discharge, not by array size.
BMS (battery management system)
Electronics that protect a lithium pack from over-charge, over-discharge, over-current and short circuit, and that balance cells. A BMS does not replace correct controller settings or fusing.
Bulk charge
The first charging stage, delivering full available current until the battery reaches its absorption voltage.

D-H

Derating
Reduction of nameplate output for real conditions — temperature, soiling, wiring and ageing. A 550 W module rarely delivers 550 W in the field.
Depth of discharge (DoD)
The fraction of a battery’s capacity that has been used. Design DoD is the limit set to preserve cycle life: about 80% for LiFePO4, 50% for gel.
Duty cycle
The proportion of time a device is active. A water level sensor measuring for 5 seconds every 5 minutes has a duty cycle of about 1.7%, which changes system sizing completely compared with a continuous load.
Float charge
A lower voltage held after charging completes, to counter self-discharge without overcharging.

I-M

Irradiance
Instantaneous solar power per unit area, in W/m². Standard test condition is 1,000 W/m². An overcast winter day may be 80-150 W/m².
Insolation / peak sun hours (PSH)
Daily solar energy expressed as the number of hours at 1,000 W/m². A day with 4 PSH delivers 4 kWh/m². Always size on the worst-month value.
Low-voltage disconnect (LVD)
A controller function that disconnects the load before the battery is damaged by deep discharge. Set it above the lowest voltage your equipment tolerates.
MPPT (maximum power point tracking)
A controller that continuously adjusts its input to harvest the array’s maximum power. Typically gains 10-30% over PWM, more when array voltage greatly exceeds battery voltage.
Mismatch loss
Energy lost when panels or cells with different characteristics are connected in series or parallel. The weakest element limits the string.

P-S

Peak sun hours
See insolation.
PERC
Passivated Emitter and Rear Contact — a cell architecture with a rear passivation layer that improves efficiency by reducing recombination.
PWM (pulse width modulation)
A simple controller that clamps array voltage to battery voltage. Cheap and reliable, but wastes the difference between Vmp and battery voltage.
Round-trip efficiency
Energy out of a battery divided by energy put in. Roughly 90-95% for LiFePO4, 80-85% for lead-acid.
Soiling
Dust, sand, bird droppings or salt on the glass. In dry dusty regions, losses accumulate at roughly 1% per day without rain or cleaning.
Standby / quiescent draw
Current a device or controller consumes while idle. A controller drawing 20 mA continuously uses 5.8 Wh/day — significant on a small system.
STRING
Panels connected in series. String voltage adds; string current is limited by the lowest-current panel.

T-Z

Temperature coefficient
How output changes with cell temperature. Power coefficients are typically −0.30 to −0.45% per °C; voltage coefficients are strongly negative and matter for controller voltage limits.
Tilt angle
Panel angle from horizontal. Optimum for annual yield is roughly local latitude, but 10-15° is often better in dusty regions because it sheds dirt while limiting wind load.
Usable capacity
Nominal capacity × design depth of discharge. The only capacity number that matters when sizing autonomy.
Vmp / Voc / Isc / Imp
Voltage and current at maximum power point, open-circuit voltage, short-circuit current and current at maximum power. Voc is what you check against a controller’s voltage limit; Isc is what you check against its current limit.
Voltage drop
Loss along a conductor, proportional to length, current and resistivity, and inversely proportional to cross-section. Keep array circuits under 3% and load circuits under 2%.
Watt-peak (Wp)
Nameplate array or module rating at standard test conditions. A starting point for design, not a prediction of field output.

For worked examples using these terms, see the sizing reference or run the calculator.