Definitions as they are used in off-grid system design, not marketing. Where a term is commonly misused, the note explains the practical difference.
A-C
- Absorption charge
- The constant-voltage stage at the end of bulk charging, held until current falls to a set fraction of capacity. Too short and the battery stays undercharged; too long and it ages faster.
- Albedo
- The fraction of sunlight reflected from the ground. Snow raises it, dark soil and water lower it. Relevant to bifacial modules and to panels mounted over reflective surfaces.
- Ampere-hour (Ah)
- Charge capacity. Meaningless without a voltage — 100 Ah at 12 V is 1,280 Wh, not a fixed amount of energy.
- Autonomy
- The number of consecutive days a system can run its load with no meaningful solar input. Set by battery capacity and usable depth of discharge, not by array size.
- BMS (battery management system)
- Electronics that protect a lithium pack from over-charge, over-discharge, over-current and short circuit, and that balance cells. A BMS does not replace correct controller settings or fusing.
- Bulk charge
- The first charging stage, delivering full available current until the battery reaches its absorption voltage.
D-H
- Derating
- Reduction of nameplate output for real conditions — temperature, soiling, wiring and ageing. A 550 W module rarely delivers 550 W in the field.
- Depth of discharge (DoD)
- The fraction of a battery’s capacity that has been used. Design DoD is the limit set to preserve cycle life: about 80% for LiFePO4, 50% for gel.
- Duty cycle
- The proportion of time a device is active. A water level sensor measuring for 5 seconds every 5 minutes has a duty cycle of about 1.7%, which changes system sizing completely compared with a continuous load.
- Float charge
- A lower voltage held after charging completes, to counter self-discharge without overcharging.
I-M
- Irradiance
- Instantaneous solar power per unit area, in W/m². Standard test condition is 1,000 W/m². An overcast winter day may be 80-150 W/m².
- Insolation / peak sun hours (PSH)
- Daily solar energy expressed as the number of hours at 1,000 W/m². A day with 4 PSH delivers 4 kWh/m². Always size on the worst-month value.
- Low-voltage disconnect (LVD)
- A controller function that disconnects the load before the battery is damaged by deep discharge. Set it above the lowest voltage your equipment tolerates.
- MPPT (maximum power point tracking)
- A controller that continuously adjusts its input to harvest the array’s maximum power. Typically gains 10-30% over PWM, more when array voltage greatly exceeds battery voltage.
- Mismatch loss
- Energy lost when panels or cells with different characteristics are connected in series or parallel. The weakest element limits the string.
P-S
- Peak sun hours
- See insolation.
- PERC
- Passivated Emitter and Rear Contact — a cell architecture with a rear passivation layer that improves efficiency by reducing recombination.
- PWM (pulse width modulation)
- A simple controller that clamps array voltage to battery voltage. Cheap and reliable, but wastes the difference between Vmp and battery voltage.
- Round-trip efficiency
- Energy out of a battery divided by energy put in. Roughly 90-95% for LiFePO4, 80-85% for lead-acid.
- Soiling
- Dust, sand, bird droppings or salt on the glass. In dry dusty regions, losses accumulate at roughly 1% per day without rain or cleaning.
- Standby / quiescent draw
- Current a device or controller consumes while idle. A controller drawing 20 mA continuously uses 5.8 Wh/day — significant on a small system.
- STRING
- Panels connected in series. String voltage adds; string current is limited by the lowest-current panel.
T-Z
- Temperature coefficient
- How output changes with cell temperature. Power coefficients are typically −0.30 to −0.45% per °C; voltage coefficients are strongly negative and matter for controller voltage limits.
- Tilt angle
- Panel angle from horizontal. Optimum for annual yield is roughly local latitude, but 10-15° is often better in dusty regions because it sheds dirt while limiting wind load.
- Usable capacity
- Nominal capacity × design depth of discharge. The only capacity number that matters when sizing autonomy.
- Vmp / Voc / Isc / Imp
- Voltage and current at maximum power point, open-circuit voltage, short-circuit current and current at maximum power. Voc is what you check against a controller’s voltage limit; Isc is what you check against its current limit.
- Voltage drop
- Loss along a conductor, proportional to length, current and resistivity, and inversely proportional to cross-section. Keep array circuits under 3% and load circuits under 2%.
- Watt-peak (Wp)
- Nameplate array or module rating at standard test conditions. A starting point for design, not a prediction of field output.
For worked examples using these terms, see the sizing reference or run the calculator.