This is the working reference we use when sizing off-grid solar systems for monitoring, security, agriculture and telecom sites. It is deliberately conservative: every factor below assumes real site conditions — dust, heat, ageing and imperfect installation — rather than laboratory values.

Core formulas

Quantity Formula Notes
Daily energy E = Σ (P × h × n) P = device watts, h = hours per day, n = quantity
Array size Wp = E × 1.25 / (PSH × 0.70) 1.25 design margin, 0.70 system efficiency
Battery capacity Wh = E × autonomy days / DoD DoD = usable depth of discharge
Battery capacity (Ah) Ah = Wh / system voltage Use nominal voltage, not charge voltage
Controller current I = (Wp / V) × 1.25 Then round up to a standard rating
Voltage drop ΔV = 2 × L × I × 0.0175 / A L in metres one-way, A in mm², copper
Cold Voc Voc_cold = Voc_STC × (1 + β × (T_min − 25)) β typically −0.0025 to −0.0035 per °C

Typical device loads

Use these as a starting point only — measure the actual site where possible. Labels on equipment are usually peak, not average.

Device Typical continuous draw Notes
Fixed CCTV camera (day) 3-6 W IR illumination can double this at night
PTZ camera 15-40 W Only while moving; higher in cold weather with heaters
NVR / recorder 10-25 W Scales with disk count and channels
4G / LTE router 2-8 W average Transmit bursts reach 1-2.5 A at 12 V
Radar water level sensor 5-12 W while measuring Duty-cycled, seconds per reading
Data logger / RTU 0.1-1 W Dominant load on many monitoring sites
GNSS receiver 1-4 W Continuous, sensitive to brownout
PoE switch (4 port) 8-20 W Plus the PoE budget of attached devices
Gate motor (sliding) 5-15 A surge Seconds per cycle; battery must carry surge
Weather station (full) 1-5 W Heated sensors add significantly

System efficiency breakdown

The 0.70 figure in the array formula is not arbitrary. It is the product of the losses below. If any of them is worse than typical, reduce the factor.

Loss Typical value Worse case
Soiling (dust on glass) 3-8% 20-35% in dry dusty seasons
Cell temperature 8-12% 15-20% at 70°C cell temperature
Controller conversion 3-6% (MPPT) 15-25% with PWM on a high-voltage array
Cable and connection loss 2-4% 8-10% with undersized cable
Battery round-trip 5-10% (lithium) 15-20% (lead-acid)
Mismatch and ageing 2-5% 8-10% at end of module life

Autonomy selection

Site situation Autonomy Reasoning
Weekly access, reliable roads 2-3 days Short outage is recoverable
Monthly access 4-5 days Must ride out typical cloud runs
Monsoon / harmattan climate 5-7 days Extended low-yield periods are seasonal
Inaccessible in the wet season 7-10 days Access and yield fail at the same time
Safety or security critical 7 days plus redundancy Outage cost exceeds equipment cost

System voltage selection

Array size Recommended voltage Reason
Under 300 Wp 12 V Lower component cost, short cable runs
300-800 Wp 24 V Halves current, keeps cable practical
800-3000 Wp 48 V Controller and cable limits become binding above this
Over 3000 Wp 48 V or high-voltage DC Specialist design required

Voltage drop limits

Keep total DC voltage drop under 3% for the array circuit and under 2% for the load circuit. On a 12 V system, 3% is only 0.36 V — which is why 12 V installations are so sensitive to cable length and why 24 V is the practical minimum for anything beyond a few metres.

Cross-section Current at 12 V, 3% drop, 10 m Current at 24 V, 3% drop, 10 m
2.5 mm² ~3.5 A ~7 A
4 mm² ~5.6 A ~11 A
6 mm² ~8.4 A ~17 A
10 mm² ~14 A ~28 A
16 mm² ~22 A ~45 A

Controller matching

  • MPPT is worth the premium whenever array voltage exceeds battery voltage by more than about 20%
  • Check the controller’s maximum PV input voltage against cold-morning open-circuit voltage, not datasheet Voc at 25 °C
  • Check the controller’s continuous output current against the load peak, not its maximum PV current
  • Leave 20-25% current headroom for array expansion and hot-weather derating

Battery depth of discharge

Chemistry Design DoD Cycle life impact
LiFePO4 80% 3,000-6,000 cycles at this depth
Gel lead-acid 50% Deeper cycling halves life quickly
AGM lead-acid 50% Slightly lower cycle life than gel
Flooded lead-acid 30-50% Requires watering and ventilation

Use the sizing calculator to apply these formulas to your own load list, or send us the site details and we will return a sized configuration.